gpg: failed to create temporary file '/var/lib/lurker/.#lk0x56a88100.hantslug.org.uk.22431': Permission denied
gpg: keyblock resource '/var/lib/lurker/pubring.gpg': Permission denied
gpg: Signature made Thu Mar 4 12:38:47 2021 GMT
gpg: using RSA key 9B00C02592448A31EF971B350F3EE001F02A3E20
gpg: Can't check signature: No public key
On Thu, 4 Mar 2021 12:09:21 -0000
rmluglist2--- via Hampshire <hampshire@???> wrote:
Hello rmluglist2---,
>a) the length of the cable or
Unlikely; Cable runs of up to 100m should be okay. Difficult to reach
in a domestic setting.
>b) the quality of the cable or
More likely.
You also mentioned (lack of) cable movement. Don't be so sure -
expansion/contraction as temperature changes may play a part.
To say nothing of routing. Esp. if the cable ever goes under floor or
via the loft. Then rodents and all sorts of other critters might enter
the mix.
--
Regards _
/ ) "The blindingly obvious is
/ _)rad never immediately apparent"
He's got all the answers
Ask Mr Waverley - The Cortinas
--
Please post to: Hampshire@???
Web Interface:
https://mailman.lug.org.uk/mailman/listinfo/hampshire
LUG URL:
http://www.hantslug.org.uk
--------------------------------------------------------------